Current Transformer, Split Core 100-200 Amps.
Indoor low current use only, not sealed or impregnated. The models
below also have optional ratio's. Secondary ratings of 5 amp 1 amp,
2 amp and 100ma are all available. 5 amp secondary units are priced below.
 
Two model groups, SP and SPS.  SP use a stainless steel screw clamp
band securing the two core halves the SPS uses a UV resistant nylon band.
Add $10.00 to the published price for non-5 amp secondary.
 
A
B
C
D
E
1-SP
0.84
2.00
3.31
3.09
0.61
2-SP
0.90
2.13
4.13
4.00
0.50
3-SP
2.19
3.25
4.56
4.72
0.61
5-SP
2.88
4.25
5.56
5.69
0.61
7-SP
2.88
6.25
7.63
5.63
0.61
bullet
Frequency: 50 - 400 Hz
bullet
Insulation Class: 600V, 15KV BIL
bullet
Meets or exceeds UL 1244, ANSI C-57-13 and IEC stand.
bullet
Leads are #16 AWG, 36" long
You may also need a shorting block for insertion and removal of the
split core CT's into your system.
1ea. SB-4TC (IKU-4SC)  $40.00ea. (4 Contacts with cover)
1ea. SB-6TC (IKU-6SC)  $50.00ea. (6 Contacts with cover)
Model 1SP  1SP Sheet
P / N Ratio Burden Price
1SP100 100:5 1VA $120.00
1SP150 150:5 1.5VA $120.00
1SP200 200:5 2.5VA $120.00
1SP250 250:5 2.5VA $120.00
1SP300 300:5 3VA $120.00
1SP400 400:5 4VA $120.00
Model 3SP   3SP Sheet
P / N Ratio Burden Price
3SP400 400:5 5VA $130.00
3SP500 500:5 5VA $130.00 
3SP600 600:5 7.5VA $130.00
3SP800 800:5 7.5VA $130.00 
3SP1000 1000:5 10VA $130.00
3SP1200 1200:5 10VA $130.00 
Model 5SP    5SPSheet
P / N Ratio Burden Price
5SP600 600:5 7.5VA $170.00
5SP800 800:5 7.5VA $170.00
5SP1000 1000:5 10VA $170.00
5SP1200 1200:5 10VA $170.00
5SP1500 1500:5 12.5VA $195.00
5SP2000 2000:5 50VA $235.00
Model 7SP  7SP Sheet
P / N Ratio Burden Price

  7SP600

600:5 2.5VA 190.00

  7SP800

800:5 5.0VA 190.00
7SP1000 1000:5 10VA 190.00
7SP1200 1200:5 15VA 200.00
7SP1500 1500:5 20VA 225.00
7SP2000 2000:5 40VA 225.00
7SP2500 2500:5 50VA 225.00
7SP3000 3000:5 50VA 270.00
 
Caution
Serious injury can result from electrical shock.  Be sure
to turn off the electrical  power before installing any meter.
Fire can result from loose electrical connections. 
Ensure that all electrical connections are secure.  If you do not
understand theses instructions hire an experienced electrician
to install the meter for you.  Help is also available from the
factory buy phone or email.