| P8500 |
4MB memory, 50 data recorders (800 channels), waveform recorders and
transient detection. |
4458 |
| P8400 |
2MB memory, 20 data recorders (320 channels), advanced sag/swell
detection |
3188 |
| Form Factor |
|
|
|
| E0 |
Form 9S Base - 57-277 V (autoranging) 3-Element, 4-Wire |
- |
| F0 |
Form 35S Base - 120-480 V (autoranging) 2-Element, 3-Wire |
- |
| G0 |
Form 36S Base - 57-277 V (autoranging) 2 1/2-Element, 4-Wire |
-282 |
| H0 |
Form 39S with neutral current input (15 Terminal Base) - 57-277 V (autoranging)
3-Element, 4-Wire |
282 |
| J0 |
Form 76S with neutral current input (15 Terminal Base) - 57-277 V (autoranging)
2 1/2-Element, 4-Wire |
282 |
| E8 |
Form 9 FT21 Switchboard (meter + case) with break out panel |
1311 |
| F8 |
Form 35 FT21 Switchboard (meter + case) with break out panel |
1311 |
| G8 |
Form 36 FT21 Switchboard (meter + case) with break out panel |
1311 |
| E9 |
Form 9 FT21 Switchboard (meter + case) with break out cable |
1000 |
| F9 |
Form 35 FT21 Switchboard (meter + case) with break out cable |
1000 |
| G9 |
Form 36 FT21 Switchboard (meter + case) with break out cable |
1000 |
| Current Inputs |
|
|
|
| C |
Standard (5 Amp nominal, 20 Amp full scale current input) |
|
| E |
1 Amp nominal (10 Amp full scale current input) |
|
| H |
Extended Range current inputs from 10mA to 20 Amp; not available for
switchboard Products |
605 |
| Voltage Input |
|
|
|
| 0 |
Standard (see Form Factor above) |
|
| Power Supply |
|
|
|
| E |
Form 9S, 36S, 39S, 76S (socket) and Form 9,36 (FT21 switchboard):
120-277 VAC. Form 35S (socket) |
|
|
and Form 35 (FT21 switchboard): 120-480 VAC. Powered from the meter's
voltage connections. |
|
| G |
9S,36S (socket) and 9,36 (FT21 switchboard): 57-70 VAC. Powered via
meter's voltage connections. |
135 |
|
NOT AVAILABLE on Form 35S (socket) and Form 35 (FT21 Switchboard) -
select the aux. pigtail option. |
|
| H |
Auxiliary Power Pigtail: 65-120 VAC (power from external source)65-120
VAC, 80-160 VDC |
135 |
| J |
Auxiliary Power Pigtail: 160-277 VAC (power from external source)
160-277 VAC, 200-350 VDC |
135 |
| System Frequency |
|
|
|
| 5 |
50Hz. |
|
|
|
| 6 |
60Hz. |
|
|
|
| Communications |
|
|
|
| A0 |
COM1: RS-232/485 port |
-1182 |
|
COM2: RS-485 port |
|
|
|
COM3: Infrared port |
|
|
| C1 |
COM1: RS-232/485 port |
894 |
|
COM2: 33.6k universal internal modem (RJ11) |
|
|
COM3: Infrared port |
|
|
|
COM4: Ethernet (10BaseT) |
|
| C2 |
Same as C1, but with RJ31 connector for the modem |
894 |
| C5 |
COM1: RS-232/485 port |
1182 |
|
COM2: 33.6k universal internal modem (RJ11) + Outage Dial Back |
|
|
COM3: Infrared port |
|
|
|
COM4: Ethernet (10BaseT) |
|
| C6 |
Same as C5, but with RJ31 connector for the modem |
1182 |
| E0 |
COM1: RS-232/485 port |
523 |
|
COM2: RS-485 port |
|
|
|
COM3: Infrared port |
|
|
|
COM4: Ethernet (10BaseT) |
|
| F0 |
COM1: RS-232/485 port |
935 |
|
COM2: RS-485 port |
|
|
|
COM3: Infrared port |
|
|
|
COM4: Ethernet (10BaseFL) |
|
|
Note: Not available with FT21 switchboard Form Factors (E8, F8, G8, E9,
F9, G9) |
|
| M1 |
COM1: RS-232/485 port |
435 |
|
COM2: 33.6k universal internal modem (RJ11) |
|
|
COM3: Infrared port |
|
|
|
COM4: RS-485 port |
|
|
| M2 |
Same as M1, but with RJ31 connector for the modem |
435 |
| M5 |
COM1: RS-232/485 port |
723 |
|
COM2: 33.6k universal internal modem (RJ11) + Outage Dial Back |
|
|
COM3: Infrared port |
|
|
|
COM4: RS-485 port |
|
|
| M6 |
Same as M5, but with RJ31 connector for the modem |
723 |
| Input/Output Option |
|
|
|
| A |
None |
|
|
|
| B |
4 Form C Digital Outputs , 3 Form A Digital Inputs |
364 |
| Security |
|
|
|
|
| 0 |
Password protected, no security lock |
|
| 1 |
Password protected with security lock enabled |
|