Digitec Meter Alternatives.
Texmate Replacements from 2080-D337X.
 
DIGITEC TEXMATE Inc.  
Model Recommended Model VARIATION NOTES:
   
2610 DX-35  / DL-40- w/ID01/ID03 Verify Output OPT
2630 DL-40H-DR-PS1-IT10 Verify Output OPT
2650 DX-35 / DL-40-w/-IA01 to IA11 Verify Output OPT
2660 DL-40H-DR-PS1-IT10 Verify Output OPT
2810A DX-35-DR-PS1-ID01/ID02  
2811A DX-45-DR-PS1-ID01/ID02  
2812A DX-45-DR-PS1-ID01/ID02  
2820A DX-45-DR-PS1-ID01/IP01 Verify Output OPT
2825A DI-50E w/ID01-ID03, IP01 Verify Output OPT
2830A DL-40H Verify Output OPT
2840A DI-50E w/IS01, IS02 Verify Output OPT
2845A DI-50E w/IS01, IS02 Verify Output OPT
2850A DI-50E w/IA01-IA11 Verify Output OPT
2860A DI-50E w/IT02 Verify Output OPT
2870A DI-50E w/ID01-ID03, IP01, IP02 Verify Output OPT
2875A DI-50T w/ID01-ID03, IP01, IP02 Verify Output OPT
2880A DI-50E w/RS232 Output Option Verify Output OPT
2890A DI-50E w/ID01-ID03, IP01, IP02 Verify Output OPT
2894A DI-50E w/ID01-ID03, IP01, IP02 Verify Output OPT
D311X DX-35, DX-45 or DL-40 Verify Output OPT
D312X DX-35, DX-45 or DL-40 Verify Output OPT
D313X DL-40H-DR-PS1-IT08 Verify Output OPT
D314X DL-40-DR-PS1-IS01/IS02 Verify Output OPT
D315X DL-40-DR-PS1-IA01 to IA11 Verify Output OPT
D316X DL-40H-DR-PS1-IT10 Verify Output OPT
D317X DL-40-DR-PS1-IA01 to IA11 Verify Output OPT
D3220 DI-50E Verify Inp/Output OPT
D3221 DI-50E Verify Inp/Output OPT
D3240 DI-50E Verify Output OPT
D331X DX-35/DX-45  
D332X DL-40-DR-PS1-IP01/IP02  
D333X DL-40H-DR-PS1-IT10  
D334X DL-40-DR-PS1-IS01/IS02  
D335X DL-40-DR-PS1-IA01 to IA11  
D336X DL-40H-DR-PS1-IT10  
D337X DL-40-DR-PS1-IA01 to IA11  
   
Digi Tec Ordering Code Conversion
Model Example  2812-A01FX-23521

Texmate

Code

Input Range Pos/Neg.

Code

10A= 3.5 Digits DX35
11A= 4.0 Digits DL40
12A= 4.5Digit DX45
F= Digital Offset and scale DL40PSF
D= Red/Orange Display N/A
C= Digital Limits Form C Relays OR11 (1 10 Amp)
C= Digital Limits Form C Relays OR12 (2 10 Amp)
T= Serial Data Output S2 RS232 output
H= Analog Output AIC4-20mA
H= Analog Output AIV0-10VDC
X= Full scale reading  
00= 99.99mV IDO2
01= 999.9mV IDO2
02= 9.999mV IDO2
03= 99.99V IDO1
04= 999.9V IDO1