Home

Manufactures
Accuenergy
Crompton
Schneider
Sifam
Texmate

Meters
Digital Switchboard
 Digital Transducer  
Electric Meters
Energy Meters
Revenue Grade
Smart Meters
Surplus
Watt-Hour

Relays
Indicating
Non Indicating

Transducers
Indicating
Non Indicating

Transformers
Current
Potential

Switches
Salzer


Ordering
                                           

Power Measurement.

2 Pulse or Alarm Relays, Analog / Digital outputs,

Ethernet communication. Ships in 1 Day.

 

Alpha 30 Data Sheet.
Alpha 30

Alpha 30 digital metering system benefits from optional pulsed and digital outputs.

Allows  measured parameters to be communicated to Scada building/power measurement system.

Ethernet communication allows for remote network viewing of all parameters from a great distance.

On board meter memory stores Min and Max values. Energy measurement includes import and export  values of kWh, kVArh,

 
Parameters Alpha 30  (56 Count)
Single Phase
Three Phase
User Selectable 3PH 3W/4W
ON site CT Primary Programmable 5 / 1A
On Site CT Secondary Programmable
On Site PT Primary Programmable
On site selection Auto Scroll+Fixed Screen
User Selectable low Current Supression
Min / Max Storage of Voltage and Current
Phase Reversal Indication
Parameter Screen Recall
Energy Count Storage
Configuration of Instruments via Modbus
User Assignable Resister for Modbus
Password Protection
Run Hour, ON Hour, Number of Interruptions
Program Energy format & Energy rollover count
EMC Compatibility
System Voltage
System Current
Phase Voltage (L1-N, L2-N, L3-N)
Line Voltage (L1-L2, L2-L3, L1-L3)
Line Current (IL1 , IL2, IL3)
Frequency
Neutral Current
System Power Factor
Power Factor Per Phase (Cos°1, 2, 3
Phase Angle Per Phase (°1, °2, °3)
System Active Power (kW)
Active Power Per Phase (KW1, KW2, KW3)
System Re-Active Power (kVAr)
Re-Active Power Per Phase (KVAr1, KVAr2, KVAr3)
System Apparent Power (kVA)
Apparent Power Per Phase (kVA1, kVA2, kVA3)
Active Energy kWH
Import kWh (8 digit resolution)
Export kWh (8 digit resolution)
Reactive Energy KVArh
Import kVArh (8 digit resolution)
Export kVArh (8 digit resolution)
Apparent Energy kVAh (8 digit resolution)
kAh (8 digit resolution)
System Current Demand
System KVA Demand
KW Import Demand
KW Export Demand
Max Current Demand
Max KVA Demand
Max KW Import Demand
Max KW Export Demand
% THD of System Voltage
% THD of System Current
% THD of all three line voltages (L-L)
% THD of all three Phase voltages (L-N)
% THD of all three phase current
Phase Reversal Indication
Utility Active Energy (kWh)
 
Prices:
Alpha 30 with Aux. Power 100-250VAC
Alpha 30  No options.
Alpha 30 RS485 Port-Modbus
AP30-23EUZZZ000000 
AP30-23EURZZ000000
 $  449.00
 $  459.00
Alpha 30  RS-485, 2 Pulse Output AP30-23EURDZ000000   $  479.00
Alpha 30 RS-485, 2 Analog Output AP30-23EURZ2000000   $  479.00
Alpha 30 RS-485, 2 Analog & 1 Pulse O. AP30-23EURS2000000   $  499.00
Alpha 30 Ethernet Port AP30-23EUZZZE00000   $  499.00
Alpha 30 with Aux. Power 12-48VDC
Alpha 30  No Options.
Alpha 30  RS485 Port-Modbus
AP30-23EDZZZ000000 
AP30-23EDRZZ000000 
 $  449.00
 $  459.00
Alpha 30  RS-485, 2 Pulse Output  AP30-23EDRDZ000000   $  479.00
Alpha 30  RS-485, 2 Analog Output AP30-23EDRZ2000000   $  479.00
Alpha 30  RS-485, 2 Analog &1 Pulse O. AP30-23EDRS2000000   $  499.00
Alpha 30  RS-485, Ethernet Port AP30-23EDRZZE00000   $  499.00