Power Measurement, Ethernet comm. option.

2 Pulse or Alarm Relays, Analog / Digital outputs,

RS485, Ethernet communications available.

 
Alpha 30 Digital Panel Meter
Alpha 30 Data Sheet.

Comparison INT-1530  vs. Alpha 30
Comparison INT-1630 vs. Alpha 30
Alpha 30

Alpha 30 digital metering system benefits from optional pulsed and digital outputs.

Allows  measured parameters to be communicated to Scada building/power measurement system.

Ethernet communication allows for remote network viewing of all parameters from a great distance.

On board meter memory stores Min and Max values. Energy measurement includes import and export  values of kWh, kVArh,

 
Parameters Alpha 30  (56 Count)
Single Phase
Three Phase
User Selectable 3PH 3W/4W
ON site CT Primary Programmable 5 / 1A
On Site CT Secondary Programmable
On Site PT Primary Programmable
On site selection Auto Scroll+Fixed Screen
User Selectable low Current Supression
Min / Max Storage of Voltage and Current
Phase Reversal Indication
Parameter Screen Recall
Energy Count Storage
Configuration of Instruments via Modbus
User Assignable Resister for Modbus
Password Protection
Run Hour, ON Hour, Number of Interruptions
Program Energy format & Energy rollover count
EMC Compatibility
System Voltage
System Current
Phase Voltage (L1-N, L2-N, L3-N)
Line Voltage (L1-L2, L2-L3, L1-L3)
Line Current (IL1 , IL2, IL3)
Frequency
Neutral Current
System Power Factor
Power Factor Per Phase (Cos°1, 2, 3
Phase Angle Per Phase (°1, °2, °3)
System Active Power (kW)

PRICES:
Active Power Per Phase (KW1, KW2, KW3)
System Re-Active Power (kVAr)
Re-Active Power Per Phase (KVAr1, KVAr2, KVAr3)
System Apparent Power (kVA)
Apparent Power Per Phase (kVA1, kVA2, kVA3)
Active Energy kWH
Import kWh (8 digit resolution)
Export kWh (8 digit resolution)
Reactive Energy KVArh
Import kVArh (8 digit resolution)
Export kVArh (8 digit resolution)
Apparent Energy kVAh (8 digit resolution)
kAh (8 digit resolution)
System Current Demand
System KVA Demand
KW Import Demand
KW Export Demand
Max Current Demand
Max KVA Demand
Max KW Import Demand
Max KW Export Demand
% THD of System Voltage
% THD of System Current
% THD of all three line voltages (L-L)
% THD of all three Phase voltages (L-N)
% THD of all three phase current
Phase Reversal Indication
Utility Active Energy (kWh)
AP30-21JDZZZ000000 Sys:1Ph; I/P:120V, 1/5A; Aux:12-48V DC; 0.2 Accuracy 275
AP30-21JUZZZ000000 Sys:1Ph; I/P:120V, 1/5A; Aux:100-250V ACDC; 0.2 Accuracy 275
AP30-21JURZZ000000 Sys:1Ph; I/P:120V, 1/5A; Aux:100-250V ACDC; RS 485; 0.2 Accuracy 300
AP30-21JURDZ000000 Sys:1Ph; I/P:120V, 1/5A; Aux:100-250V ACDC; RS 485; 2 Pulse O/P; 0.2 Acc. 325
AP30-21JURZ2000000 Sys:1Ph; I/P:120V, 1/5A; Aux:100-250V ACDC; RS 485; 2 Analog O/P; 0.2 Acc. 325
AP30-21JURS2000000 Sys:1Ph; I/P:120V, 1/5A; Aux:100-250V ACDC; RS 485; 1 Pulse; 2 Analog O/P; 0.2 Acc. 350



AP30-23JDZZZ000000 Sys:3Ph; I/P:120V, 1/5A; Aux:12-48V DC; 0.2 Accuracy 300
AP30-23JUZZZ000000 Sys:3Ph; I/P:120V, 1/5A; Aux:100-250V ACDC; 0.2 Accuracy 300
AP30-23JURZZ000000 Sys:3Ph; I/P:120V, 1/5A; Aux:100-250V ACDC; RS 485; 0.2 Accuracy 325
AP30-23JURDZ000000 Sys:3Ph; I/P:120V, 1/5A; Aux:100-250V ACDC; RS 485; 2 Pulse O/P; 0.2 Accuracy 350
AP30-23JURZ2000000 Sys:3Ph; I/P:120V, 1/5A; Aux:100-250V ACDC; RS 485; 2 Analog O/P; 0.2 Accuracy 350
AP30-23JURS2000000 Sys:3Ph; I/P:120V, 1/5A; Aux:100-250V ACDC; RS 485; 1 Pulse; 2 Analog O/P; 0.2 Acc. 375



AP30-238DZZZ000000 Sys:3Ph; I/P:208V, 1/5A; Aux:12-48V DC; 0.2 Accuracy 300
AP30-238UZZZ000000 Sys:3Ph; I/P:208V, 1/5A; Aux:100-250V ACDC; 0.2 Accuracy 300
AP30-238URZZ000000 Sys:3Ph; I/P:208V, 1/5A; Aux:100-250V ACDC; RS 485; 0.2 Accuracy 325
AP30-238URDZ000000 Sys:3Ph; I/P:208V, 1/5A; Aux:100-250V ACDC; RS 485; 2 Pulse O/P; 0.2 Acc. 350
AP30-238URZ2000000 Sys:3Ph; I/P:208V, 1/5A; Aux:100-250V ACDC; RS 485; 2 Analog O/P; 0.2 Acc. 350
AP30-238URS2000000 Sys:3Ph; I/P:208V, 1/5A; Aux:100-250V ACDC; RS 485; 1 Pulse; 2 Analog O/P; 0.2 Acc. 375



AP30-23GDZZZ000000 Sys:3Ph; I/P:480V, 1/5A; Aux:12-48V DC; 0.2 Accuracy 300
AP30-23GUZZZ000000 Sys:3Ph; I/P:480V, 1/5A; Aux:100-250V ACDC; 0.2 Accuracy 300
AP30-23GURZZ000000 Sys:3Ph; I/P:480V, 1/5A; Aux:100-250V ACDC; RS 485; 0.2 Accuracy 325
AP30-23GURDZ000000 Sys:3Ph; I/P:480V, 1/5A; Aux:100-250V ACDC; RS 485; 2 Pulse O/P; 0.2 Accuracy 350
AP30-23GURZ2000000 Sys:3Ph; I/P:480V, 1/5A; Aux:100-250V ACDC; RS 485; 2 Analog O/P; 0.2 Accuracy 350
AP30-23GURS2000000 Sys:3Ph; I/P:480V, 1/5A; Aux:100-250V ACDC; RS 485; 1 Pulse; 2 Analog O/P; 0.2 Acc. 375



AP30-23GDZZZ400000 Sys:3Ph; I/P:480V, 1/5A; Aux:12-48V DC; 0.2 Acc; 400 Hz 350
AP30-23GUZZZ400000 Sys:3Ph; I/P:480V, 1/5A; Aux:100-250V ACDC; 0.2 Accuracy; 400 Hz 350
AP30-23GURZZ400000 Sys:3Ph; I/P:480V, 1/5A; Aux:100-250V ACDC; RS 485; 0.2 Accuracy; 400 Hz 375
AP30-23GURDZ400000 Sys:3Ph; I/P:480V, 1/5A; Aux:100-250V ACDC; RS 485; 2 Pulse O/P; 0.2 Acc; 400 Hz 400
AP30-23GURZ2400000 Sys:3Ph; I/P:480V, 1/5A; Aux:100-250V ACDC; RS 485; 2 Analog O/P; 0.2 Acc; 400 Hz 400
AP30-23GURS2400000 Sys:3Ph; I/P:480V, 1/5A; Aux:100-250V ACDC; RS 485; 1 Pulse; 2 Analog O/P; 0.2 Acc; 400 Hz 425