Home Accuenergy Conzerv Crompton Digital-Switchboard Meters To Go Texmate Meters Utility Meters Watthour Meters Wilbac Meters . Alternatives For: Analogic Digitec EIL KEP Modutec Newport Precision Digital Red Lion Simpson Westcon . Current Transformers Switches-Disconnect Switches-Instrument Temp Sensors Transducers Ordering Info Order via Email Order Fax Quotation Fax
| |
CROMPTON TRIP RELAY ORDERING CODES.
252 SERIES AC PROTECTOR TRIP
RELAY.
A complete relay model
number example:
252-PVOU-RMBX-C6-EA-S1-DE.
Some Options listed below
effect published prices seen on other pages.
Choose the code from each group to complete
the relay number
PVOU=Function,
RMBX=Input,
C6=Frequency,
EA= Relay action,
S1=amount of time delay,
DE= Auxiliary power supply.
Function
PAOU=SINGLE PHASE OVER CURRENT
PAUU=SINGLE PHASE UNDER CURRENT
PVOU=SINGLE PHASE OVER VOLTAGE
PVUU=SINGLE PHASE UNDER VOLTAGE
PVHU=SINGLE PHASE OVER VOLTAGE WITH EXTERNAL
TIME DELAY
PVZU=SINGLE PHASE UNDER VOLTAGE WITH EXTERNAL
TIME DELAY
PVAU=3 PHASE 3 WIRE OVER VOLTAGE
PVKU=3 PHASE 3 WIRE UNDER VOLTAGE
PVCU=3 PHASE 3 WIRE OVER VOLTAGE WITH EXTERNAL
TIME DELAY
PVJU=3 PHASE 3 WIRE UNDER VOLTAGE WITH
EXTERNAL TIME DELAY
PVPU=3 PHASE 4 WIRE OVER VOLTAGE
PVVU=3 PHASE 4 WIRE UNDER VOLTAGE
PVSU=3 PHASE 4 WIRE OVER VOLTAGE WITH EXTERNAL
TIME DELAY
PVXU=3 PHASE 4 WIRE UNDER VOLTAGE WITH
EXTERNAL TIME DELAY
PHOU=OVER FREQUENCY PROTECTOR
PHUU=UNDER FREQUENCY PROTECTOR
PSFU=PHASE BALANCE
PSGU=PHASE BALANCE w/UNDER V PROT.
PVRU=PHASE SEQUENCE AND PHASE FAILURE
Specification
SPEC. US STANDARD
Input
PKBX=100 VOLTS L/L
PMBX=110 VOLTS L/L
POBX=115 VOLTS L/L
PQBX=120 VOLTS L/L
P7BX=127 VOLTS L/L
RLBX=200 VOLTS L/L
RMBX=208 VOLTS L/L
R4BX=220 VOLTS L/L
RQBX=230 VOLTS L/L
RRBX=240 VOLTS L/L
RSBX=250 VOLTS L/L
R9BX=280 VOLTS L/L
RUBX=380 VOLTS L/L
SCBX=400 VOLTS L/L
SBBX=415 VOLTS L/L
SHBX=440 VOLTS L/L
SDBX=450 VOLTS L/L
DABX=460 VOLTS L/L
SEBX=480 VOLTS L/L
ZOBX=57.7 VOLTS L/N
NXBX=63.5 VOLTS L/N
ZIBX=66.4 VOLTS L/N
PABX=69 VOLTS L/N
Z4BX=69.3 VOLTS L/N
PKBX=100 VOLTS L/N
PMBX=110 VOLTS L/N
POBX=115 VOLTS L/N
PQBX=120 VOLTS L/N
P7BX=127 VOLTS L/N
RMBX=208 VOLTS L/N
R4BX=220 VOLTS L/N
RRBX=240 VOLTS L/N
R6Bx=277 VOLTS L/N
RWBX=288 VOLTS L/N346 VOLT
Relay
VOLT FREE DRY CONTACT DP/DT
Frequency
C4= 400Hz
C5= 50Hz
C6= 60Hz
C7= 50/60Hz
C8=45/65Hz
Relay
EA= Energize (STD)- PVO/PVP ONLY
EB=DE-Energize *** - PVO/PVP ONLY
EA=RELAY Energize ***
EB=RELAY DE-Energize (STD)
Option
NT=NO TIME DELAY
S1=TIME DELAY SET TO 10 SECONDS
S2=TIME DELAY SET TO 20 SECONDS
S3=TIME DELAY SET TO 30 SECONDS
S4=TIME DELAY SET TO 1 SECOND
S5=TIME DELAY SET TO 5 SECONDS
S0=TIME DELAY SET TO ? SECONDS
Auxiliary
AD=100 VOLTS 50HZ
AE=110 VOLTS 50HZ
AF=115 VOLTS 50HZ
AG=120 VOLTS 50HZ
AL=220 VOLTS 50HZ
AM=230 VOLTS 50HZ
AN=240 VOLTS 50HZ
AW=415 VOLTS 50HZ
AX=440 VOLTS 50HZ
AY=480 VOLTS 50HZ
DE=110 VOLTS 60HZ
DF=115 VOLTS 60HZ
DG=120 VOLTS 60HZ
DL=220 VOLTS 60HZ
DM=230 VOLTS 60HZ
DN=240 VOLTS 60HZ
DP=277 VOLTS 60HZ
DW=415 VOLTS 60HZ
DX=440 VOLTS 60HZ
DY=480 VOLTS 60HZ
FE=110 VOLTS 400HZ
FF=115 VOLTS 400HZ
FG=120 VOLTS 400HZ
FL=220 VOLTS 400HZ
FM=230 VOLTS 400HZ
FN=240 VOLTS 400HZ
FX=440 VOLTS 400HZ
FY=480 VOLTS 400HZ
BC=12 VOLTS DC
BD=24 VOLTS DC
NR=48 VOLTS DC
PM=110 VOLTS DC
PQ=120 VOLTS DC
Z2=125 VOLTS DC
Z1=135 VOLTS DC
Option
CT=CALIBRATION AT ? DEG. C
SP=PRESET SET POINT AT ?
TD=PRESET DELAY ? SECONDS
|