239-Meter Relay Prices. Options include: inputs, scales, power supplies.

 Part Number Generator, option List and Complete Prices.

Product Type

Function

Specification

Input

Scale

Auxiliary

Option (RTD ONLY)

Relay

Option 

Option 

Part Number

             239 Meter Relay Specification Sheet    239 Panel Meter Relay Physicals  
 
239 Series Analog Meter Relays    
SYSTEM OPERATION CODE PRICE
1 relay,  2 setpoints LOW operation for level control, Upscale de-energized and Downscale energized INT-1543 415.09
 1 relay,  1 set point   HIGH operation, Upscale energized and Downscale de-energized  239-301 415.09
2 relays,  2 setpoints  HIGH and LOW operation, Mid band de-energized, outside band energized   239-302 474.54
2 relays,  2 setpoints HIGH and HIGH operation – Both Upscale energized and Downscale de-energized  239-303 474.54
2 relays,  2 setpoints  HIGH and LOW operation, Mid band energized, outside band de-energized  239-304 474.54
 2 relays,  2 setpoints LOW and LOW operation – Both Upscale de-energised and Downscale energized  239-305 474.54
1 relay,  1 set point    LOW operation, Upscale de-energized and Downscale energized  239-307 415.09
2 relays,  2 setpoints RTD Operated, Mid band de-energized, outside band energized  239-30R 554.35
2 relays,  2 setpoints Thermocouple Operated, Mid band de-energized, outside band energized 239-30T 554.35
       
METER RELAY - STANDARD INPUTS ONLY - NON STANDARD UPON REQUEST   ADD
Rated 1A - 15A AC/scaled for CT motor start duty (internal CT permits10 x FLC for 10 sec, 2 x FLC continuously)   46.60
Any Standard AC Voltage Input, 0/300V Maximum   44.99
METER RELAY - OPTIONAL EXTRAS   ADD
Calibrated at customer specified temperature   53.56
Finger knob setpoint adjusters   29.99
Dual Scale OR special     32.14
Latching Relays, remove auxiliary supply to reset - 239 & 244 Only - Specify Both, High only or Low Only   53.56
Clamp band fixing - for panels over 10mm thick - Option 239 - Standard 057   34.28
       
Red line on instrument dial   8.57
Coloured band on instrument dial - per colour   21.42
TPC-Time proportional control (proportional plus derivative control)  239 & 244 Only   46.60
Center Zero, Off-Set Zero or Suppressed Zero   46.60
Retro Fit mounting plate     38.56
PD Option Heavily damped movement   47.13
240 series time delay     107.12
AUXILIARY SUPPLY OPTIONS   ADD
AC:    110V, 220V, 230V, 240V ±20%   50/60Hz - Specify   0.00
AC:    63 to 480V specify nominal voltage, +/-20%   50 or 60Hz   72.84
DC:    12V, 24V, 48V, 110V, 125V, 135V - Specify   59.99