Integra 513-514 Three phase Meter from Crompton.
 
Measurement of fundamental electrical parameters, integrating high
accuracy measurement technology with the simplicity and visibility of
a single display system. Got Questions? call or email.
Integra 513 Measures A, V, L-L, Hz.
Integra 514 Measures A, V, L-N, Hz.
Features:
Programmable Primary of CT
Accuracy 1.0% in V & I
DIN Quadratic housing 96 x96MM
Measures up to 7 parameters
Electrical Connections: 3P3W or #P4W
High Contrast 3 Line, 4 digit display
Build the model number by following this example.
Description: Meter +System+ W  Volts In+ Current In+ Aux+ Options
Code
System
 Price
3
3 phase 3 wire
 $ 166.40
4
3 phase 4 wire
 $ 176.80
Measured Voltage Input
 
10
110-120V L-L, 58-69V L-L
 N/C
19
190-240V L-L, 110-139V L-L
 N/C
38
380-480V L-L, 219-277V L-N
 N/C
Measured Current Input
 
LA
1 Amp AC
 N/C
LS
5 Amp AC
 N/C
Auxiliary Power
 
10
110-120V
 N/C
19
190-240V
 N/C
38
380-480V
 N/C
SP
Self Powered
 N/C
Benefits
Totally new look MDI, 9 measurements in one unit, Programmable C.T. ratios
Readable in bright sunlight, Replaces 3 combined MDI &
1 Voltmeter Simple to use, Measures down to 2.5% of nominal input, High overload capability
Features
High contrast LCD, Large characters, Standard 96 x 96mm DIN case
Self powered or Auxiliary powered, Average sensing, Password protected
Designed to meet world-wide standard approvals for safety and performance, EMC and LVD.
Burden:
Voltage: Each line 0.2VA approx.
Current: Each phase 0.6VA approx.
Overload Capability:
Continuous: 120% of nominal (600V Max)
Short Duration: 2 x nominal for one second
Current:
Continuous: 120% of nominal
Auxiliary Supply
A.C. voltage: 100 - 120V 190 - 240V 380 - 480V -10% of lower nominal +20% of upper nominal
Burden 3VA approx.
Enclosure: Size: 96 x 96 mm DIN Material: Flame retardant to UL94V-0/V-2
Terminals: M3.5 captive screw & clamp
Accuracy Class
Voltage: +1.5% of nominal
Current: +1.5% of nominal
Current Demand: 3% of nominal
Surge Voltage
Test: IEC 801-5 High Frequency Disturbance: 4.2kV peak IEC 255
Display High contrast LCD & Annunciation Characters 10.5mm high 3 lines of data,
4 digits per line 4 digit resolution with a floating decimal point for each value
All parameters available via single button operation cascading through 4 screens
Comprehensive set-up facility via two buttons Update time 7.5 seconds approx. for
 A & V, 1/8 of demand integration time for current demand.