Home Accuenergy Conzerv Crompton Digital-Switchboard Meters To Go Texmate Meters Utility Meters Watthour Meters Wilbac Meters . Alternatives For: Analogic Digitec EIL KEP Modutec Newport Precision Digital Red Lion Simpson Westcon . Current Transformers Switches-Disconnect Switches-Instrument Temp Sensors Transducers Ordering Info Order via Email Order Fax Quotation Fax
| |
Load Management AC System Panel Monitors
|
Multi-task Management of Loads,
Feeders, Incomers - EM 3000 Series
This panel meter series comes with TOU feature for
better energy monitoring and management. The Smart Demand Controller, with
prediction and control output features, enables demand control and
optimization.
Data Sheet
|
 |
|
Multi-task Management of Loads,
Feeders, Incomers - EM 3000 Series
This series comes with TOU feature for
better energy monitoring and management. The Smart Demand Controller, with
its prediction and
control output features, enables demand
control and optimization.
Features
 | True RMS |
 | Suitable for HT & LT |
 | Frequency & RPM measurement |
 | Records run hours, off hours, and interruptions |
 | Logging of High-Low profiles, all power parameters date/time |
 | Accuracy Class 1.0, 0.5 and 0.2 |
 | Auto scaling from kilo to mega |
 | Auto scrolling |
 | Auto reset option |
 | Up to 10 years' backup of data and settings |
 | Built-in RTC and RS 485 port |
 | Portable kit option with clamp-on CTs & voltage probes |
 | Maximized resolution through floating decimal point |
 | Sharp, high visibility display |
 | Import/Export option |
 | Compact size Bezel 192 x 144mm. Behind bezel 110mm |
 | Quick & easy installation |
 |
TOU option
|
The EM 3000 series
meters are used to measure:
 | Voltage: Phase to Phase and average |
 | Voltage: Phase to Neutral and average |
 | Voltage: Neutral to Earth |
 | Voltage: Phase angle |
 | Current: Phase-wise, Average and Neutral Current |
 | Current: Phase angle |
 | % Total Harmonic Distortion of voltage & current wave forms phase-wise |
EM 3000 series has 3 different models, choose by applications:
Power &
Energy Monitor EM 3360 Accuracy Class 0.2
$580.00
 | Voltage: Phase to Phase, average, Phase to Neutral, average, |
 | Voltage: Neutral to Earth. |
 | Phase angle: Voltage and Current phase wise |
 | Current: Phase-wise, Average and Neutral Current |
 | % Total Harmonic Distortion of voltage & current wave forms phase-wise
|
 | Monitoring of all power & energy parameters - total as well as phase
wise |
 | 4 high and 4 low profiles for instantaneous parameters with day, date
and time |
 | Optional TOU for 8 intervals and 6 seasons for energy parameters |
Tri-vector Monitor EM 3480
Accuracy Class 0.2
$790.00
 | EB Meter cross-check |
 | Monitors demand parameters: Instantaneous & maximum demand, with day,
date & time |
 | Synchronizes automatically with EB meter |
 | Records High-Low profile of maximum demand |
 | Generates Demand Profile at 19 Demand Levels for setting realistic
demand targets according to user-programmed Demand Level 0 and step size
|
 | Optional TOU for 8 intervals & 7 seasons for energy and demand
parameters |
Smart Demand
Controller EM 3460
Accuracy Class 0.2
$990.00
 | User programmable upper limit and lower limit of kW or kVA parameters,
essential load and prediction interval for sophisticated demand control
|
 | Demand intervals selectable from 1 to 30 minutes |
 | Demand control through unique predictive technique and sliding window
integration which leads to: Reduced energy losses, improved load factor &
minimal disruption in operations |
 | 3 changes over potential-free control outputs for: Predicted demand
exceeds target, demand exceeds target & restore load |
 | Spare load and predicted demand parameters gives advance warning for
planned demand control |
|
Technical Specification |
|
Sensing |
3 Phase, 3 Wire / 4 Wire (field
configurable) |
|
Measurement |
True RMS |
|
Voltage Input |
110 to 415 V nominal ( Range 80 - 500 V)
|
|
Current Input |
5 or 1 Amp (Factory set ) nominal
|
|
Maximum Current |
150 % of nominal |
|
Burden on PT or CT |
0.2 VA Max |
|
Accuracy ( For V, A, PF, & all Power &
Energy Parameters ) |
|
Class 1.0 |
+ (0.2 % of Full Scale + 0.8 % of reading +
1 digit ). |
|
Class 0.5 |
+ (0.1 % of Full Scale + 0.4 % of reading +
1 digit ). |
|
Class 0.2 |
+ (0.05% of Full Scale + 0.15% of reading +
1 digit ). |
|
Accuracy of Hz |
0.2 % of reading |
|
Accuracy of ø |
10 ° ( 20 % to 150 % of Full Scale )
|
|
Display update |
Every 1 second ( Demand Par - 15 Secs )
|
|
Keyboard |
Easy to operate sealed Membrane type
|
|
Auxiliary Supply |
Factory Set, Single 50 Hz 240V ( 190 - 270 V
) or
110V ( 85 - 130V ). Burden 5VA max. |
|
Frequency |
50 Hz + 5%, 60 Hz |
|
Power Factor |
0.5 PF Lag - Unity - 0.8 PF Lead
|
|
Dimensions |
Bezel 192 x 144mm.
Depth behind Bezel 110mm |
|
Weight |
1800 gms. Approximately |
|
Panel Cut out |
186 x 138mm ( + 1 - 0 mm) |
|
Operating temperature |
0 - 60 ° C ambient |
|
|