Home
Accuenergy
Conzerv
Crompton
Digital-Switchboard
Meters To Go
Texmate Meters
Utility Meters
Watthour Meters
Wilbac Meters
.
Alternatives For:
Analogic
Digitec
EIL
KEP
Modutec
Newport
Precision Digital
Red Lion
Simpson
Westcon
.
Current Transformers
Switches-Disconnect
Switches-Instrument
Temp Sensors
Transducers
Ordering Info
Order via  Email
Order Fax
Quotation Fax
 
 
 
 
 

Load Management AC  System Panel Monitors

Multi-task Management of Loads, Feeders, Incomers - EM 3000 Series
This panel meter series comes with TOU feature for better energy monitoring and management. The Smart Demand Controller, with prediction and control output features, enables demand control and optimization.
Data Sheet
Multi-task Management of Loads, Feeders, Incomers - EM 3000 Series
This series comes with TOU feature for better energy monitoring and management. The Smart Demand Controller, with its prediction and
control output features, enables demand control and optimization.

Features

bulletTrue RMS
bulletSuitable for HT & LT
bulletFrequency & RPM measurement
bulletRecords run hours, off hours, and interruptions
bulletLogging of High-Low profiles, all power parameters date/time
bulletAccuracy Class 1.0, 0.5 and 0.2
bulletAuto scaling from kilo to mega
bulletAuto scrolling
bulletAuto reset option
bulletUp to 10 years' backup of data and settings
bulletBuilt-in RTC and RS 485 port
bulletPortable kit option with clamp-on CTs & voltage probes
bulletMaximized resolution through floating decimal point
bulletSharp, high visibility display
bulletImport/Export option
bulletCompact size Bezel 192 x 144mm. Behind bezel 110mm
bulletQuick & easy installation
bullet
TOU option
The EM 3000 series meters are used to measure:
bulletVoltage: Phase to Phase and average
bulletVoltage: Phase to Neutral and average
bulletVoltage: Neutral to Earth
bulletVoltage: Phase angle
bulletCurrent: Phase-wise, Average and Neutral Current
bulletCurrent: Phase angle
bullet% Total Harmonic Distortion of voltage & current wave forms phase-wise
EM 3000 series has 3 different models, choose by applications:
Power & Energy Monitor EM 3360  Accuracy Class 0.2    $580.00
bulletVoltage: Phase to Phase, average, Phase to Neutral, average,
bulletVoltage: Neutral to Earth.
bulletPhase angle: Voltage and Current phase wise
bulletCurrent: Phase-wise, Average and Neutral Current
bullet% Total Harmonic Distortion of voltage & current wave forms phase-wise
bulletMonitoring of all power & energy parameters - total as well as phase wise
bullet4 high and 4 low profiles for instantaneous parameters with day, date and time
bulletOptional TOU for 8 intervals and 6 seasons for energy parameters
 
 
Tri-vector Monitor EM 3480  Accuracy Class 0.2    $790.00
bulletEB Meter cross-check
bulletMonitors demand parameters: Instantaneous & maximum demand, with day, date & time
bulletSynchronizes automatically with EB meter
bulletRecords High-Low profile of maximum demand
bulletGenerates Demand Profile at 19 Demand Levels for setting realistic demand targets according to user-programmed Demand Level 0 and step size
bulletOptional TOU for 8 intervals & 7 seasons for energy and demand parameters
Smart Demand Controller EM 3460  Accuracy Class 0.2    $990.00
bulletUser programmable upper limit and lower limit of kW or kVA parameters, essential load and prediction interval for sophisticated demand control
bulletDemand intervals selectable from 1 to 30 minutes
bulletDemand control through unique predictive technique and sliding window integration which leads to: Reduced energy losses, improved load factor & minimal disruption in operations
bullet3 changes over potential-free control outputs for: Predicted demand exceeds target, demand exceeds target & restore load
bulletSpare load and predicted demand parameters gives advance warning for planned demand control

 

Technical Specification

Sensing 3 Phase, 3 Wire / 4 Wire (field configurable)
Measurement True RMS
Voltage Input 110 to 415 V nominal ( Range 80 - 500 V)
Current Input 5 or 1 Amp (Factory set ) nominal
Maximum Current 150 % of nominal
Burden on PT or CT 0.2 VA Max
Accuracy ( For V, A, PF, & all Power & Energy Parameters )
Class 1.0 + (0.2 % of Full Scale + 0.8 % of reading + 1 digit ).
Class 0.5 + (0.1 % of Full Scale + 0.4 % of reading + 1 digit ).
Class 0.2 + (0.05% of Full Scale + 0.15% of reading + 1 digit ).
Accuracy of Hz 0.2 % of reading
Accuracy of ø 10 ° ( 20 % to 150 % of Full Scale )
Display update Every 1 second ( Demand Par - 15 Secs )
Keyboard Easy to operate sealed Membrane type
Auxiliary Supply Factory Set, Single 50 Hz 240V ( 190 - 270 V ) or
110V ( 85 - 130V ). Burden 5VA max.
Frequency 50 Hz + 5%, 60 Hz
Power Factor 0.5 PF Lag - Unity - 0.8 PF Lead
Dimensions Bezel 192 x 144mm.
Depth behind Bezel 110mm
Weight 1800 gms. Approximately
Panel Cut out 186 x 138mm ( + 1 - 0 mm)
Operating temperature 0 - 60 ° C ambient