Acuvim L Series, 3 Phase Power Meter. Demand, TOU.
30
plus parameters for measurement.
True-RMS measuring parameter
4-quadrant Energy
Power Quality Analysis
Clear LCD screen
Bright White Back light
Device for an
intelligent Power distribution.
|
 |
Available
Options:
1 amp CT
input.
Low voltage
DC
power supply.
Second RS 485
port.
|
 |
 |
System or Plant
Automation system. All monitoring data is available via
digital RS485
communication port running Modbus RTU Protocol starting with the -
CL
version. Any phase current or voltage can be displayed and the
harmonic content
calculated.
Choose the model via parameters.
Meter Prices:
Acuvim-AL-D-60-5A-P1
$265.00 Standard
Acuvim-AL-D-60-1A-P1 $275.00
Optional 1 Amp CT Input.
Acuvim-AL-D-60-5A-P2 $285.00
24VDC
power supply.
Acuvim-BL-D-60-5A-P1
$295.00 Digital Pulse, alarm Output.
Acuvim-CL-D-60-5A-P1 $350.00 RS485 Communication port.
Acuvim-CL-M-60-5A-P1
$280.00 DIN Mount-No Display, RS485 Comm. port.
Acuvim-CL-D-60-1A-P1 $360.00
RS485 Communication port.
Acuvim-CL-D-60-5A-P2
$370.00 RS485 Communication port 24VDC power
supply.
Acuvim-DL-D-60-5A-P1 $350.00
RS485 Communication Optional I/O.
Acuvim-EL-D-60-5A-P1 $380.00
RS485 Communication port TOU Measurement.
Acuvim-EL-M-60-5A-P1 $330.00
DIN Mount, RS485 Comm. port, TOU Measurement,
Acuvim-KL-D-60-5A-P1 $195.00
RS485 Communication port. Energy/Power meter.
Acuvim L Series Brochure
Acuvim L Manual
Acuvim Communication hookups
How to
Program Acuvim-L Series Power Meters.
Function |
Parameter |
AL |
BL |
CL |
DL |
EL |
KL |
Real Time Measurement-60- |
Phase Voltage |
U1, U2, U3, |
> |
> |
> |
> |
> |
|
Line Voltage |
U1-2, U2-3, U3-1, |
> |
> |
> |
> |
> |
|
Current |
I1, I2, I3,LN * |
> |
> |
> |
> |
> |
> |
Power (Watts) |
P1, P2, P3, Psum |
> |
> |
> |
> |
> |
> |
Reactive Power |
Q1, Q2, Q3, Qsum |
> |
> |
> |
> |
> |
> |
Apparent Power |
S1, S2, S3, Ssum |
> |
> |
> |
> |
> |
> |
Power factor |
PF1, PF2, PF3, PF |
> |
> |
> |
> |
> |
|
Load nature |
L ?C ?R |
> |
> |
> |
> |
> |
|
Frequency |
Hz |
> |
> |
> |
> |
> |
|
Energy
Demand 15 Minute Wind. |
Energy (WattHours) |
Ep-imp, Ep-exp |
> |
> |
> |
> |
> |
> |
Reactive Energy |
Eq-imp, Eq-exp |
> |
> |
> |
> |
> |
> |
Apparent Energy |
Es |
> |
> |
> |
> |
> |
> |
Current Demand |
Dmd-L1,-L2, -L3 |
> |
> |
> |
> |
> |
|
Power Demand |
Psum, Qsum, Ssum |
> |
> |
> |
> |
> |
|
Time of Use |
Energy |
TOU 4 Tariffs, 12 Seasons, 14 Schedules |
|
|
|
|
TOU |
|
Power Quality |
Voltage Unbalance |
U_unbal |
> |
> |
> |
> |
> |
|
Current Unbalance |
I_unbal |
> |
> |
> |
> |
> |
|
Voltage THD |
V1, V2, V3 |
> |
> |
> |
> |
|
|
Current THD |
I1, I2, I3 |
> |
> |
> |
> |
|
|
Individual Harmonics |
2nd-15th Voltage-Current** |
> |
> |
> |
> |
|
|
Statistics |
Max Current Demand |
L1, L2, l3, Max |
> |
> |
> |
> |
> |
|
Max Power demand |
Psum, Qsum, Ssum |
> |
> |
> |
> |
> |
|
Max&Min Voltage |
|
> |
> |
> |
> |
> |
|
Max&Min Current |
|
> |
> |
> |
> |
> |
|
|
Running Hour |
Hour |
> |
> |
> |
> |
> |
> |
|
Load Running Hour |
Hour |
|
|
|
> |
> |
> |
I/O |
Energy Pulse Out |
2 DO. Configured-pulse out for kWh and kVar, adjustable rate & width |
|
> |
|
|
|
|
Alarm Output |
|
|
> |
|
|
|
|
Communication |
RS485 Port |
Modbus RTU |
|
|
> |
> |
> |
> |
Second RS485 Port |
Modbus RTU |
|
|
|
*** |
*** |
|
Extension I/O |
4Digital in, 2 Dig/Out |
SOE, Pulse counter, Pulse Output,
Alarm Output. |
|
|
|
*** |
*** |
|
* KL-no neutral measurement |
|
|
|
|
|
|
|
** DL Measures Harmonics from 2nd-25th *** Optional |
|
|
|
|
|
Options Input/Output Power
Analysis
BL- Alarm Output
- One (1) alarm parameter may be set within a specified time
interval.
- If indicated parameter is over or under its
setting limit and persists
- over the specified time interval, the event will be recorded
with time
- stamps and trigger the Alarm DO output. The indicated parameter
can
- be selected from any of the 31 parameters available.
Pulse Output
- Two Digital outputs can be configured as pulse output for kWh
and kVarh.
- The pulse rate and width can be set.
CL -Communication
- RS485, Industry standard Modbus RTU protocol
|
|