Acuvim L Series, 3 Phase Power Meter. Demand, TOU.
30 plus parameters for measurement.  
True-RMS measuring parameter
4-quadrant Energy
Power Quality Analysis
Clear LCD screen
Bright White Back light
Device for an intelligent Power distribution.
Acuvim-L
Available Options:
1 amp CT input.
Low voltage
DC power supply.
Second RS 485 port.

 

Acuvim meter fits DIN or ANSI round cutout Poly Meter enclosure with meter cutout, front door
System or Plant Automation system. All monitoring data is available via
digital RS485 communication port running Modbus RTU Protocol starting with the -
CL version. Any phase current or voltage can be displayed and the harmonic content
calculated. Choose the model via parameters. 
 
Meter Prices:
Acuvim-AL-D-60-5A-P1  $265.00   Standard
Acuvim-AL-D-60-1A-P1  $275.00   Optional 1 Amp CT Input.
Acuvim-AL-D-60-5A-P2  $285.00   24VDC  power supply.
Acuvim-BL-D-60-5A-P1  $295.00   Digital Pulse, alarm Output.
Acuvim-CL-D-60-5A-P1  $350.00   RS485 Communication port.
Acuvim-CL-M-60-5A-P1 $280.00    DIN Mount-No Display, RS485 Comm. port.
Acuvim-CL-D-60-1A-P1  $360.00   RS485 Communication port.
Acuvim-CL-D-60-5A-P2  $370.00   RS485 Communication port  24VDC power supply.
Acuvim-DL-D-60-5A-P1  $350.00   RS485 Communication Optional I/O.
Acuvim-EL-D-60-5A-P1  $380.00   RS485 Communication port TOU Measurement.
Acuvim-EL-M-60-5A-P1  $330.00   DIN Mount, RS485 Comm. port, TOU Measurement,
Acuvim-KL-D-60-5A-P1  $195.00   RS485 Communication port. Energy/Power meter.
Acuvim L Series Brochure
Acuvim L Manual
Acuvim Communication hookups
How to Program Acuvim-L Series Power Meters.
 
 
Function Parameter AL BL CL DL EL KL
Real Time Measurement-60- Phase Voltage U1, U2, U3, > > > > >  
Line Voltage U1-2, U2-3, U3-1, > > > > >  
Current I1, I2, I3,LN * > > > > > >
Power (Watts) P1, P2, P3, Psum > > > > > >
Reactive Power Q1, Q2, Q3, Qsum > > > > > >
Apparent Power S1, S2, S3, Ssum > > > > > >
Power factor PF1, PF2, PF3, PF > > > > >  
Load nature L ?C ?R > > > > >  
Frequency Hz > > > > >  

Energy

Demand
15 Minute Wind.
Energy  (WattHours) Ep-imp, Ep-exp > > > > > >
Reactive Energy Eq-imp, Eq-exp > > > > > >
Apparent Energy Es > > > > > >
Current Demand Dmd-L1,-L2, -L3 > > > > >  
Power Demand Psum, Qsum,  Ssum > > > > >  
Time of Use Energy TOU 4 Tariffs, 12 Seasons, 14 Schedules         TOU  
Power Quality Voltage Unbalance U_unbal > > > > >  
Current Unbalance I_unbal > > > > >  
Voltage THD V1, V2, V3 > > > >    
Current THD I1, I2, I3 > > > >    
Individual Harmonics 2nd-15th Voltage-Current** > > > >    
Statistics Max Current Demand L1, L2, l3, Max > > > > >  
Max Power demand Psum, Qsum, Ssum > > > > >  
Max&Min Voltage   > > > > >  
Max&Min Current   > > > > >  
Running Hour Hour > > > > > >
Load Running Hour Hour       > > >
I/O Energy Pulse Out 2 DO. Configured-pulse out for kWh and kVar, adjustable rate & width   >        
Alarm Output     >        
Communication RS485 Port Modbus RTU     > > > >
Second RS485 Port Modbus RTU       *** ***  
Extension I/O 4Digital in, 2 Dig/Out SOE, Pulse counter, Pulse Output,                Alarm Output.       *** ***  
*  KL-no neutral measurement              
** DL Measures Harmonics from 2nd-25th   *** Optional          
 
Options Input/Output Power Analysis
BL- Alarm Output
  • One (1) alarm parameter may be set within a specified time interval.
  • If indicated parameter is over or    under its setting limit and persists
  • over the specified time interval, the event will be recorded with time
  • stamps and trigger the Alarm DO output. The indicated parameter can
  • be selected from any of the 31 parameters available.
Pulse Output
  • Two Digital outputs can be configured as pulse output for kWh and kVarh.
  • The pulse rate and width can be set.
CL -Communication
  • RS485, Industry standard Modbus RTU protocol